What We Do
Indoor Climate System
Indoor Climate System
RoofVent®
LHW
- RoofVent® LHW incorporates a plate heat exchanger that recovers energy from the extract air and transmits it to the supply air.
Technical Data |
LHW-5 |
LHW-8 |
LHW-10 |
Air flow rate(㎥/h) |
5,000 |
8,000 |
10,000 |
Heating Capacity(kcal/h) |
Up to 55,087 |
Up to 116,470 |
Up to 143,496 |
Cooling Capacity(kcal/h) |
- |
- |
- |
Range(m x m) |
21 x 21 |
26 x 26 |
32 x 32 |
Weight(㎏) |
491 |
692 |
706 |
Description
- RoofVent® is a roof ventilation unit for supplying fresh air and removing extract air. RoofVent® LHW incorporates a plate heat exchanger that recovers energy from the extract air and transmits it to the supply air.
LHKW
- RoofVent® LHKW is similar in design to RoofVent® LHW: It supplies fresh air and maintains the right temperature in high spaces and incorporates a plate heat
exchanger.
Technical Data |
LHKW-5 |
LHKW-8 |
LHKW-10 |
Air flow rate(㎥/h) |
5,000 |
8,000 |
10,000 |
Heating Capacity(kcal/h) |
Up to 55,087 |
Up to 116,470 |
Up to 143,496 |
Cooling Capacity(kcal/h) |
Up to 39,465 |
Up to 79,619 |
Up to 98,203 |
Range(m x m) |
21 x 21 |
26 x 26 |
32 x 32 |
Weight(㎏) |
521 |
744 |
758 |
On-Site Installation
TopVent®
DHV
- TopVent® DHV has been specially developed for use in highspaces. Thanks to its high performance and efficient airdistribution, the unit has a large coverage area.
Because fewer units are needed, investment and installation costs are lower.
Technical Data |
DKV-5 |
DKV-10 |
Air flow rate(㎥/h) |
4,100 |
10,000 |
Heating Capacity(kW) |
Up to 68,545 |
Up to 143,396 |
Cooling Capacity(kW) |
Up to 39,465 |
Up to 98,203 |
Range(m x m) |
19 x 19 |
32 x 32 |
Weight(㎏) |
139 |
210 |
On-Site Installation
- Three unit sizes, two-speed fans, different heater battery types and a whole string of accessories provide a tailored solution for any large space. Special batteries
(steam, electric heating coils) are also available.
DKV
- TopVent® DKV is similar in design to recirculation air heating unit TopVent® DHV, but it can be used for cooling as well as heating. The major difference is the
built-in condensate separator. In addition, the unit is insulated.
Technical Data |
DHV-5 |
DHV-10 |
Air flow rate(㎥/h) |
5,000 |
10,000 |
Heating Capacity(kW) |
Up to 55,087 |
Up to 143,396 |
Cooling Capacity(kW) |
- |
- |
Range(m x m) |
19 x 19 |
32 x 32 |
Weight(㎏) |
95 |
152 |
On-Site Installation
- TopVent® DKV, too, is available with numerous output ratings and installed in various places.
- TopVent® DKV units are suitable for heating and cooling.
Air-Injector
- Hoval Air-Injector provides constant, draught-free airflow into occupied area regardless of air temperature and volume, and used for high-rise structures such as
production hall, gym, Hall Lobby, etc.
Technical Data |
3 |
10 |
Air flow rate(㎥/h) |
3,000 |
10,000 |
Mounting Height(m) Max |
8.5 |
13.0 |
Noise Levels(dBA) Max |
65 |
69 |
Range(m x m) Max |
17 x 17 |
32 x 32 |
Weight(㎏) |
34 |
65 |
On-Site Installation