The development of Hoval ServeLine concentrated on the specific requirements for data centers in financial(bank, insurance, etc), telecommunication and IT companies.
ServeLine cools the IT environment indirectly with high-efficiency plate heat exchangers. The air in the server room remains completely separated from the fresh air;
this eliminates the possibility of dust or variations in humidity affecting highly sensitive IT equipments.
120kW
Cooling capacity at 24°C supply air / 38°C extract air (delta T = 14 K)
Up to 17°C outside air; 100% indirect free cooling
Up to 26°C / 40%r.H. outside air - adiabatic cooling no mechanical cooling needed
25.750 m³/h supply air volume
103kW
Cooling capacity at 21°C supply air / 33°C extract air (delta T = 12 K)
Up to 15°C outside air; 100% indirect free cooling
Up to 24°C / 40%r.H. outside air - adiabatic cooling(no mechanical cooling needed)
25.750 m³/h supply air volume
ProcessLine, Heat Recovery Ventilation
The ProcessLine system combines the extraction and purification of polluted process air with ventilation and airconditioning via heat exchanger.
In this way, ProcessLine reduces the ventilation heat requirement by up to 98 % compared to systems without heat recovery
ProcessClean dry
High-capacity dry filter
Space-saving, sturdy modular construction for a long service life
Optimum adjustment to requirements with a selection of filter materials, dust extraction systems, safety engineering for fire/explosion protection
Pre-separation of coarse dirt provides protection against wear
Long service life through dimensionally stable, self-supporting filter elements (up to 8 years in 3-shift operation)
Efficient jet-pulse cleaning system for problem-free continuous operation
Maintenance friendly, with large access doors
Increased safety for personnel through operation and maintenance on the clean-gas side
ProcessClean oil
Oil/emulsion mist separator
Space-saving, sturdy modular construction for a long service life
Filter material combinations adjusted to suit requirements for low energy consumption and the required separation efficiency
Cleaning is facilitated through pre-separation of coarse dirt and patented spray-cleaning unit
Long filter element service life (up to 6 years in 3-shift operation)
Self-regenerating and washable filter elements for problem-free continuous operation
Simple maintenance through easy replacement of filter elements with tool-free quick-release mechanism
ProcessClean mix
High-capacity wet separator
Space-saving, sturdy modular construction for a long service life
Optimum adjustment to requirements through selection of various separation variants and sludge extraction systems
No clogging of the filter elements, constant suction rate
Regeneration of the scrubbing liquid by means of desludging, dust sedimentation and manual or automatic sludge extraction in combination with automatic fresh water makeup
Simple and dust-free maintenance
The safest solution where the extract air contains sticky, glowing, combustible or explosive substances
ProcessVent
Decentralised compact unit for the infeed of fresh air, disposal of extract air and heat recovery from process air
Integrated heating/cooling coil for regulation of the supply air temperature
Air distribution via displacement flow ventilation outlet or via supply air ducts
Maintenance friendly, with large access doors
Dirt-resistant plate heat exchanger in corrosion-protected, oil-tight design, with bypass for energy recovery control
RoofVent / TopVent
Decentralised A/C units
Heat recovery from room air
Ventilation of assembly areas
Recirculation heating and cooling for storage areas
High-efficiency air distribution
ProcessNet
Control of the overall system
Ensures maximum energy efficiency
Visualisation directly at the unit
Quick and easy commissioning thanks to ready-to-connect units with I&C components